Back to the facilities work sheetTRC facilities docs

FOH key light balance (LEKO FOH 1 ignores DMX)

Rendered from the working notes KEY-BALANCE.md on 2026-10-11.

FOH key light balance (2026-10-10, live desk on the lighting PC)

Answer

Fixtures

fid name type, mode DMX dimmer other channels position (m)
1 LEKO FOH 1 ETC Source Four LED Series 2 Tungsten HD, Direct - Strobe off - Fan auto (8 ch) 1.33-40 ch 8 (1.40), 8 bit, linear 1-5 R/RY/C/B/BM (baseline 255/181/149/255/255), 6-7 dummy x -1.0, y -3.5, z 3.8, aim (-0.8, 1.5)
2 LEKO FOH 2 same type and mode 1.41-48 ch 8 (1.48) same x 1.0, y -3.5, z 3.8, aim (0.8, 1.5)
201 FOH SPOT 1 (console: FRONT WASH 1) Chauvet Intimidator Spot 260X, 14 ch 1.381-394 ch 11 (1.391) pan 1-2, tilt 3-4, colour 6, gobo 7, focus 10, shutter 12 (= 6, open) x -1.5, y -3.0, z 3.8
202 FOH SPOT 2 (console: FRONT WASH 2) same type and mode 1.395-408 ch 11 (1.405) same x 1.5, y -3.0, z 3.8

Raw DMX before the test (universe 1)

when lekos ch 33-48 FOH SPOTs ch 381-408
19:37 (round 1, before) 255,181,149,255,255,0,0,0, 255,181,149,255,255,0,0,0 121,214,56,227,0,0,0,0,0,0,0,6,0,0, 126,147,56,227,0,0,0,0,0,0,0,6,0,0
19:40 (round 2, before) same, but dimmer 140 on both same
19:51 (round 3, before) same, but dimmer 25 on both same

The before values changed because another agent recalled looks on the desk at 19:39:09 and later. Each round restored to whatever it found.

Method

Luma (round 2, 900x506 frames, 0-255 luma, added over both-off)

light at 204 (80 %) mean added, whole frame lit pixels (>8) pool mean pool p90 pool p99
LEKO FOH 1 0.31 3 (noise)
LEKO FOH 2 4.95 71,773 13.0 20.0 38.0
FOH SPOT 1 (201) 3.13 57,019 20.8 33.8 43.1
FOH SPOT 2 (202) 4.42 73,179 25.3 50.5 57.8

Verdict

Desk-side change (written, committed, not deployed)

Restore proof

round job restored at universe 1, all 512 channels, before vs after
1 1372 19:38:18 identical; key dimmers 0/0/0/0 as found
2 1389 19:41:41 identical; lekos 140/140, spots 0/0 as found
3 1412 19:51:50 identical; lekos 25/25, spots 0/0 as found